Setup Parameters
Baud Rate
Baud Rate sets the bit rate of the CAN messages (not the frequency at which the messages are sent). The range of values that can be entered is 0 to 65535
however only the values indicated in the Setup Parameters Table should be used. A value other than these will cause the MIM01 to change the Baud Rate
value to 500kbit/s on the next power cycle.
Timer
The timer value is in milliseconds (ms). A smaller value means data will be sent more frequently, a larger value means data will be sent less frequently. The
range of values that can be entered is 0 to 65535 however the minimum value that should be entered is 10. Below this value data values may be repeated on
successive cycles. If a value of 0 is entered the MIM01 will change it to 1 on the next power cycle.
Frequency output can be calculated as follows:
Freq = (1/Timer) * 1000
The Timer value for a required frequency can be calculated as follows:
Timer = (1/Freq) * 1000
Some example Timer values are shown against the frequency output.
Extended Identifiers
Extended Identifiers can be set either ON or OFF. If they are off the CAN identifier type will be standard (11 bit). If they are on the CAN identifier type will be
extended (29 bit). The Standard Identifier type allows 2048 different CAN message identifiers or message “names”. The Extended Identifier type allows
436207616 different CAN message identifiers. The identifier type should be set to match the CAN data logging equipment that the MIM01 is connected to.
Setting the False option will turn Extended Identifiers off. Clicking the True option will turn Extended Identifiers on.